What was found
TUL - FOUND FLOORBEAM STATION 380 UPPER CHORD ANGLE AFT SIDE CORRODED AT FLOORBOARD FASTENER HOLE RBL 32 INCHES. CUT OUT DAMAGED AREA AND INSTALLED DOUBLER/FILLER REPAIR PER SRM 53-10-8 PAGES 45-48. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - FOUND FLOORBEAM STATION 380 UPPER CHORD ANGLE AFT SIDE CORRODED AT FLOORBOARD FASTENER HOLE RBL 32 INCHES. CUT OUT DAMAGED AREA AND INSTALLED DOUBLER/FILLER REPAIR PER SRM 53-10-8 PAGES 45-48. (M)