What was found
TUL - FOUND UPPER CHORD ANGLE OF WALKWAY FLOORBEAM CORRODED. REMOVED CORROSION, INSTALLED 301.5 HARD DOUBLER .040 PER AARD 51-40-00-1 28 FPG NR 1 LOCKS THROUGH WEB 10 F26 HI-LOCKS THROUGH UPPER LEG. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - FOUND UPPER CHORD ANGLE OF WALKWAY FLOORBEAM CORRODED. REMOVED CORROSION, INSTALLED 301.5 HARD DOUBLER .040 PER AARD 51-40-00-1 28 FPG NR 1 LOCKS THROUGH WEB 10 F26 HI-LOCKS THROUGH UPPER LEG. (M)