What was found
TUL - FOUND FLOORBEAM CRACKED ALONG UPPER EDGE BELOW AND INBOARD OF ROLLER TRAY. REMOVED THE CRACKED WEB SECTION 2.25 INCH BY 8 INCH LONG IN FLOORBEAM AND MANUFACTURED AND INSTALLED FILLER AND FLOORBEAM DOUBLERS SRM 53-00-1. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - FOUND FLOORBEAM CRACKED ALONG UPPER EDGE BELOW AND INBOARD OF ROLLER TRAY. REMOVED THE CRACKED WEB SECTION 2.25 INCH BY 8 INCH LONG IN FLOORBEAM AND MANUFACTURED AND INSTALLED FILLER AND FLOORBEAM DOUBLERS SRM 53-00-1. (M)