CLIMBING THROUGH FL180 ELEC AC BUS LT EICAS MESSAGE DISPLAYED. CHECKLIST PERFORMED AND APU WAS STARTED. APU POWERED LEFT MAIN A/C BUS ELEC GEN OFF LT EICAS MESSAGE REMAINED ON WITH FAILED LEFT IDG. REMOVED AND REPLACED IDG AT LEFT ENG IAW AMM 24-11-01. RUNUP ENGINE CHECKED OPS OK. SERVICED IDG. FOUND NO LEAKS. (M)