What was found
DFW INFLIGHT T1181/07 - UNABLE TO RETRACT NOSE GEAR AFTER TAKEOFF. RAN CHECKLIST. NO DAMAGE TO NOSE GEAR AREA. FOUND NOSE STRUT FLAT. REPLACED SCHRADER VALVE AND SERVICED NOSE GEAR. SYSTEM GROUND CHECKED NORMAL OPERATION.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DFW INFLIGHT T1181/07 - UNABLE TO RETRACT NOSE GEAR AFTER TAKEOFF. RAN CHECKLIST. NO DAMAGE TO NOSE GEAR AREA. FOUND NOSE STRUT FLAT. REPLACED SCHRADER VALVE AND SERVICED NOSE GEAR. SYSTEM GROUND CHECKED NORMAL OPERATION.