BOTTOM OF RIGHT CUSP IS CORRODED AROUND LIGHTENING HOLE AT STATION 545 TO 547. INSTALLED NEW CUSP SHEET AT RIGHT STATION 503 TO 598 PER AARD 53-20-00-16.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BOTTOM OF RIGHT CUSP IS CORRODED AROUND LIGHTENING HOLE AT STATION 545 TO 547. INSTALLED NEW CUSP SHEET AT RIGHT STATION 503 TO 598 PER AARD 53-20-00-16.