What was found
FLOORBOARD SUPPORT HAS 3 EACH NUT PLATES BROKEN BETWEEN STATION 328 AND 312 APPROXIMATELY 47 INCHES FROM RIGHT SIDEWALL. CORROSION OUT OF LIMITS. INSTALLED NEW FLOORBOARD SUPPORT PER SRM 51-10-02-0G.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOORBOARD SUPPORT HAS 3 EACH NUT PLATES BROKEN BETWEEN STATION 328 AND 312 APPROXIMATELY 47 INCHES FROM RIGHT SIDEWALL. CORROSION OUT OF LIMITS. INSTALLED NEW FLOORBOARD SUPPORT PER SRM 51-10-02-0G.