What was found
FLOORBOARD SUPPORT CRACKED AT FASTENER HOLE LOCATED BETWEEN STATION 312 AND STATION 328 27 INCHES FROM RIGHT SIDEWALL. INSTALLED NEW INTERCOSTAL PER SRM 51-10-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOORBOARD SUPPORT CRACKED AT FASTENER HOLE LOCATED BETWEEN STATION 312 AND STATION 328 27 INCHES FROM RIGHT SIDEWALL. INSTALLED NEW INTERCOSTAL PER SRM 51-10-02.