What was found
PANEL SUPPORT CHANNEL HAS FRETTING DAMAGE BOTTOM SIDE AT BODY STATIONS 663R TO 673R, 27 INCHES OUTBOARD OF BEACON. REMOVED AND REPLACED CHANNEL PER SRM 51-40-02-0G AND SRM 51-40-05-0G.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PANEL SUPPORT CHANNEL HAS FRETTING DAMAGE BOTTOM SIDE AT BODY STATIONS 663R TO 673R, 27 INCHES OUTBOARD OF BEACON. REMOVED AND REPLACED CHANNEL PER SRM 51-40-02-0G AND SRM 51-40-05-0G.