What was found
CRACKED INTERCOSTAL UNDER FLOOR TO SIDEWALL SUPPORT AT STRINGER 25 RIGHT BETWEEN BODY STATIONS 500F AND 500G. REPAIRED INTERCOSTAL PER SRM 51-20-01-0G AND 51-40-02-0G.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACKED INTERCOSTAL UNDER FLOOR TO SIDEWALL SUPPORT AT STRINGER 25 RIGHT BETWEEN BODY STATIONS 500F AND 500G. REPAIRED INTERCOSTAL PER SRM 51-20-01-0G AND 51-40-02-0G.