What was found
RIGHT PYLON NACELLE STRUT INBD FRAME CHORD IS CRACKED AT AFT OTBD RADIUS, APPROX 4 INCHES FROM TOP. R & R FRAME IAW SRM 51-10-02-0G & DWG 311T2350.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RIGHT PYLON NACELLE STRUT INBD FRAME CHORD IS CRACKED AT AFT OTBD RADIUS, APPROX 4 INCHES FROM TOP. R & R FRAME IAW SRM 51-10-02-0G & DWG 311T2350.