What was found
S1 CHECK, EMER EXIT DOOR L3 SHOWS, SLIDE ARMED LIGHT, DURING DOOR OPENING. REMOVED L3 DOOR SLIDE IAW AMM 25-62-41, RESET PLUG 35MJ IAW AMM 52-71-12. OPERATIONS TESTED GOOD IAW AMM 52-71-00. REINSTALL SLIDE IAW AMM 25-62-41 CHECKED GOOD.