What was found
AIRCRAFT WAS GROUNDED, ACTUATOR TANKS WILL NOT TAKE FUEL IN AUTO. VENTED MEL ACTUATOR TANKS WILL NOT TAKE FUEL IN AUTO, VENTED FUEL WHEN OVERRIDE. APPROXIMATELY 2200 LBS. ACTUATOR 1 AND 2200 LBS, ACTUATOR 2. REMOVED FUEL FROM ACTUATOR AND ACTUATOR 2. MAINTENANCE REPLACED THE NR 1 AND NR 2 ACTUATOR FUEL INLET VALVE ACTUATOR IAW AMM 28-28-54 AND ACCOMPLISHED A SATISFACTORY, OPS CHECK.