What was found
AIRCRAFT NOT GROUNDED. CENTER 2 ELECTRIC BRAKE POWER SUPPLY UNIT FAILURE MESSAGE RECEIVED. POWER SUPPLY PREVIOUSLY REPLACED WITH FAULTS INTERMITTENTLY REPEATING. REMOVED AND REPLACED CENTER 2 HOT BATTERY BUS POWER CONVERSION SYSTEM CONTACTOR IAW AMM DMC-B767-A-24-36-02-00A-720A-A. (CLOSED)