What was found
BLOWER VENT HAD FLOOR RUMBLE, THEN A HIGH PITCHED NOISE, AND AN ECAM CAUTION. RUMBLE AND NOISE STOPPED, AND A BURNED OUT MOTOR ODOR. REPLACED FWD AVIONICS BLOWER MOTOR IAW SMM 21-26-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BLOWER VENT HAD FLOOR RUMBLE, THEN A HIGH PITCHED NOISE, AND AN ECAM CAUTION. RUMBLE AND NOISE STOPPED, AND A BURNED OUT MOTOR ODOR. REPLACED FWD AVIONICS BLOWER MOTOR IAW SMM 21-26-01.