What was found
FLIGHT ATTENDANT NOTED AN ELECTRICAL ODOR IN THE BUSINESS CLASS GALLEY. ODOR IDENTIFIED AS UPPER FORWARD RECIRCULATION FAN MALFUNCTIONED. REMOVED AND REPLACED THE RECIRCULATION FAN IAW AMM 21-25-01. OPS CHECKED GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.