What was found
RIGHT BRAKE TEMP BEYOND SPLIT LIMITS, 390 DEGREES, -170 DEGREES. RIGHT BRAKE DOES NOT OPERATE NORMALLY ON LANDING. REPLACED NR 3 BRAKE COOLING FAN MOTOR IAW AMM 32-48-51.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.