Service difficulty report · Outflow Valve · Airbus A319112

Difficulty date
November 10, 2017
Submitted
November 14, 2017
Operation
Air carrier
Aircraft
N764US
Make and model
Airbus A319112
Aircraft serial
1369
Aircraft time
45,399 hours, 29,087 cycles
Part
Outflow Valve
Part number
VFT300B00
Part serial
2442
Condition
Faulted
Part time
45,989 hours, 26,589 cycles
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

VENT AVIONICS SYSTEM FAULT AND VENT SKIN VALVE FAULT NOTED ON ECAM ON TAKEOFF, OVERIDE WAS UNSUCCESSFULL. THE AIRCRAFT RETURNED TO CLT AND AN EMERGENCY WAS DECLARED.THE AIRCRAFT LANDED WITHOUT FURTHER INCIDENT. REPLACED SKIN AIR OUTLET VALVE (22HQ) IAW AMM 21-26-53-400-002A. AIRCRAFT WAS GROUNDED