What was found
DECLARED EMERGENCY ON APPROACH, TRAILING FLAPS STOPPED AT 5, ALTERNATE EXTENSION IAW QRH FLAPS STOPPED AT 12. LANDED WITHOUT INCIDENT. AIRCRAFT WAS GROUNDED. PERFORMED PSEU BITE TEST IAW FRM/FIM 32-09-00-810-801, SHOWED FAULT MESSAGES 32-62009 & 32-62010. PERFORMED FLAP LANDING WARNING SWITCH FAULT ISOLATION IAW FRM/FIM 32-61-00-810-815, NO FAULTS NOTED. CLEANED ELECTRICAL CONNECTOR AT SWITCH S00138. PERFORMED LEADING EDGE FLAPS AND SLATS SYSTEM OPERATION IAW AMM 27-81-00-860-801, NO FAULTS NOTED. OK FOR SERVICE.