As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
L1 DOOR DIFFICULT TO CLOSE AND LOCK WITH HANDLE, APPEARED THAT THE LOCK LINK TO DOOR HANDLE WAS OUT OF RIG. FOUND VERTICAL ADJUSTMENTS AND STOP PINS OUT OF RIG. MAINTENANCE ACCOMPLISHED DOOR RIG IAW AMM 52-11-00 AND PERFORMED SATISFACTORY OPERATIONAL CHECK.