What was found
CIDS PANEL INDICATION FOR THE R1 DOOR LOW PRESSURE. SERVICED R1 DOOR DAMPENER IAW AMM 52-10-00-614-001-A, CHECKED GOOD. OK FOR SERVICE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CIDS PANEL INDICATION FOR THE R1 DOOR LOW PRESSURE. SERVICED R1 DOOR DAMPENER IAW AMM 52-10-00-614-001-A, CHECKED GOOD. OK FOR SERVICE.