What was found
CORROSION FOUND OUT OF LIMITS ON THE FOOOR SUPPORT AT BS 947, RBL 25. REPLACED THE FLOOR SUPPORT IAW DRAWING 147A5762, 51-00-05, AND SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION FOUND OUT OF LIMITS ON THE FOOOR SUPPORT AT BS 947, RBL 25. REPLACED THE FLOOR SUPPORT IAW DRAWING 147A5762, 51-00-05, AND SRM 51-40-02.