Service difficulty report · Selector Valve · Airbus A319112

Difficulty date
December 13, 2019
Submitted
December 16, 2019
Operation
Air carrier
Aircraft
N766US
Make and model
Airbus A319112
Aircraft serial
1378
Aircraft time
50,850 hours, 32,577 cycles
Part
Selector Valve
Part number
A253130021
Condition
Leaking
Location
Mlg
Stage of operation
CR
How discovered
O
Nature of condition
K, J
Precautionary procedure
H, A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AIRCRAFT WAS GROUNDED: PILOT REPORTS WHILE IN ROUTE WE GOT GREEN SYSTEM HYD LOW PRESSURE WARNING, COMPLIED WITH ECAM SHUT OFF ENG 1 GREEN PUMP WITHIN 5MIN DECLARED EMERGENCY LANDED IN MEM. MAINTENANCE FOUND HYD LEAK AT BRAKE SELECTOR VALVE IAW AMM 32-41-11-400-001A. REPLACED BRAKE SELECTOR VALVE, OPS CHECKS GOOD. RESTOWED GRAVITY GEAR EXTN HANDLE IAW AMM 32-00-00-860-003A L/G DOORS OPS CHECK GOOD. LEAK CHECKED AND SERVICED GREEN HYDRAULIC SYSTEM. NO LEAKS NOTED. OK FOR SERVICE.