What was found
AIRCRAFT NOT GROUNDED - MULTIPLE AVIONICS FAILURES DURING CLIMBOUT, VNAV INOP, DISPLAY SOURCE 1 FEW SECONDS THEN NORMAL, MODE CONTROL PANEL (MCP) COULD NOT RESET VALUE IN ALT WINDOW TEMPORARILY. TROUBLESHOOTING ACCOMPLISHED. NO. 1 DISPLAY ELECTRONIC UNIT (DEU) FAULT, TESTED NORMAL PER FIM 31-63-00. VNAV INOP, CHECKS NORMAL PER FIM 34-61-00. RESET MODE CONTROL PANEL (MCP) AND ACCOMPLISHED TEST PER FIM 22-11-00, ALL TESTS NORMAL.