What was found
AIRCRAFT IN BASE MAINTENANCE - CHAFING, ELECTRICAL WIRING, UPPER FORWARD RH PYLON OUTBOARD AT RIB 9 (INTEGRATED DRIVE GENERATOR CABLES). REMOVED AND REPLACED ELECTRICAL WIRING (IDG CABLES), PERFORMED VOLTAGE AND FREQUENCY CHECK, PER AMM TASK 24-92-00-400-002-A, IDG CHECKS OKAY.