What was found
AIRCRAFT IN BASE MAINTENANCE: FOUND 19 X 9 INCH DELAMINATED AREA ON FLOOR PANEL 131EF BETWEEN FR 28 AND FR 31. REMOVED AND REPLACED FLOOR PANEL, REF SRM 53-02-00-300-011 PARA 2A FIG 001 AND IRM 9701 REV 1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AIRCRAFT IN BASE MAINTENANCE: FOUND 19 X 9 INCH DELAMINATED AREA ON FLOOR PANEL 131EF BETWEEN FR 28 AND FR 31. REMOVED AND REPLACED FLOOR PANEL, REF SRM 53-02-00-300-011 PARA 2A FIG 001 AND IRM 9701 REV 1.