Service difficulty report · Power Supply · Airbus A319112

Difficulty date
August 10, 2021
Submitted
August 11, 2021
Operation
Air carrier
Aircraft
N752US
Make and model
Airbus A319112
Aircraft serial
1319
Aircraft time
50,095 hours, 34,699 cycles
Part
Power Supply
Condition
Failed
Location
Emergency Lights
Stage of operation
NR
How discovered
O
Nature of condition
B
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AIRCRAFT WAS GROUNDED: REPORT OF A STRONG ELECTRICAL BURNING SMELL AROUND ROW 10. AFTER A SHORT PERIOD SMELL DISSIPATED AND NOTICED SEATS 10 DEF POWER PORTS ALL HAVE RED LIGHTS SHOWING. ACCOMPLISHED SMOKE ODOR FUME JOB CARD 26L00021001. SEAT 10 DEF POWER SUPPLY IDENTIFIED AS SOURCE. REPLACED POWER SUPPLY PER AMM 25-21-38.