Service difficulty report · Power Supply · Airbus A321211

Difficulty date
October 31, 2021
Submitted
November 4, 2021
Operation
Air carrier
Aircraft
N177US
Make and model
Airbus A321211
Aircraft serial
1517
Aircraft time
66,751 hours, 25,255 cycles
Part
Power Supply
Condition
Fault Message
Location
Zone 200 - Fuse
Stage of operation
IN
How discovered
C
Nature of condition
L
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AIRCRAFT WAS GROUNDED: WHILE ACCOMPLISHING R1 SLIDE CHANGE THE OPERATIONAL TEST OF EMERGENCY LIGHTING SYSTEM. FAILED CIDS FAULTS EMERGENCY POWER SUPPLY UNIT INT LOAD EXIT R AND L. OCCURRED. **SUPPLEMENTAL REPORT FOR AALA202111027863: MAINTENANCE APPLIED EXTERNAL POWER TO THE AIRCRAFT, PUSHED THE TEST EMERGENCY LIGHTING SYSTEM BUTTON AND LET THEM STAY ON THEN UNPLUGGED THE CONNECTORS OF THE EMERGENCY POWER SUPPLIES, WAITED 10 SECONDS AND RECONNECTED THE CONNECTOR THE POWER SUPPLIES. UNPUSHED THE TEST EMERGENCY LIGHTING SYSTEM BUTTON AND PUSHED IT BACK IN AGAIN TO RESET THE POWER SUPPLIES FAULT CLEARED AND A SATISFACTORY OPERATIONAL CHECK WAS ACCOMPLISHED ** (CLOSED)