Service difficulty report · Cooling Fan · Airbus A319112

Difficulty date
October 4, 2022
Submitted
October 18, 2022
Operation
Air carrier
Aircraft
N752US
Make and model
Airbus A319112
Aircraft serial
1319
Aircraft time
53,015 hours, 36,483 cycles
Part
Cooling Fan
Part number
3616140
Part serial
P2527CC
Condition
Leaking
Location
Zone 100 - Fuse
Part time
34,888 hours, 22,891 cycles
Component
Apu · Honeywell · 1319A
Component part number
3800708
Stage of operation
DE
How discovered
O
Nature of condition
B
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AIRCRAFT WAS GROUNDED: ON DECENT, FLIGHT ATTENDANTS REPORTED BURNING RUBBER SMELL LOCALIZED IN BACK. CREW ACCOMPLISHED SMOKE/ FUMES CHECKLIST. MAINTENANCE ISOLATED THE SOURCE OF THE ODOR TO THE APU WHICH WAS FOUND TO BE LEAKING OIL. **ORIGINAL REPORT WAS AALA202210067912** MAINTENANCE FOUND THE APU OIL COOLER AND THE APU OIL COOLING FAN (AALA202210185553) LEAKING OIL AND REPLACED THEM PER AMM 49-91-44 AND AMM 49-52-51. A SATISFACTORY LEAK CHECK WAS ACCOMPLISHED.

More about the Airbus A319-112