What was found
DFW - FLT 0544 - AFTER TAKEOFF DFW WHEN LANDING GEAR RETRACTED, THE NLG ALERT ON THE MFDU WAS ACTIVATED. RECYCLED GEAR WITH SAME RESULT. AIRCAFT RETURNED DFW AND LANDED WITHOUT INCIDENT. REPLACED SEQUENCING VALVE AND RESTRICTOR. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)