What was found
AFW - FOUND AND BLENDED OUT CORROSION ON THE UPPER SURFACE OF THE MAIN CABIN PRESSURE DECK. BLEND-OUTS EXCEEDED SRM MAXIMUM LIMITS. REMOVED CORROSION, ROTO-PEENED. ALODINED, PRIMED, AND PAINTED. APPROVED BY ENGINEERING WITH NOTED CONDITION PER MRB 767-1115. TST: 42,562.49 HRS. CYCLES, 10,821. (X)