DFW - FLT 1727 - AFTER TAKEOFF DFW WHEN LANDING GEAR RETRACTED, NOSE LANDING GEAR RED LIGHT REMAINED ILLUMINATED. EXTENDED LANDING GEAR AND ALL INDICATIONS RETURNED TO NORMAL. AIRCRAFT RETURNED TO DFW AND LANDED OVERWEIGHT WITHOUT INCIDENT. REPLACED NOSE LANDING GEAR STRUT SCHRADER VALVE PACKING. SERVICED NOSE LANDING GEAR STRUT WITH HYDRAULIC FLUID AND NITROGEN. ACCOMPLISHED NOSE LANDING GEAR RETRACTION CHECK WITH NO DEFECTS FOUND. SYSTEM GROUND CHECKED NORMAL OPERATION. ACCOMPLISHED OVERWEIGHT LANDING CHECK WITH NO DEFECTS FOUND. (M)