TUL - STRINGER 26L, UPPER SIDE CORRODED AT STATION 1008. REMOVED AND REPLACED STRINGER SPLICE PER SRM 53-10-3. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - STRINGER 26L, UPPER SIDE CORRODED AT STATION 1008. REMOVED AND REPLACED STRINGER SPLICE PER SRM 53-10-3. (M)