What was found
TUL - FOUND CORROSION AROUND BELLY DRAIN AT APPROX STATION 1331. REMOVED CORROSION PER SRM 51-21-01 AND INSTALLED REPAIR DOUBLER PER SRM 53-40-00. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - FOUND CORROSION AROUND BELLY DRAIN AT APPROX STATION 1331. REMOVED CORROSION PER SRM 51-21-01 AND INSTALLED REPAIR DOUBLER PER SRM 53-40-00. (M)