What was found
HNL - FLT 102 - AFTER TAKEOFF HNL, RT MAIN GEAR DOOR WOULD NOT CLOSE. RECYCLED GEAR DOOR, REMAINED OPEN. RETURNED HNL AND LANDED WITHOUT INCIDENT. REPLACED LANDING GEAR SELECTOR CONTROL VALVE. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)