What was found
TUL - BELLFRAME DENTED STATION 520 TOP SIDE INTO RADIUS, WEB STRINGER 22 AREA. REMOVED DAMAGED AREA AND INSTALLED REPAIR, SRM 51-40-3 .050 7075-T6, REPAIR MATERILA AND .1875 FLUSH AND PAN 'D' RIVETS. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - BELLFRAME DENTED STATION 520 TOP SIDE INTO RADIUS, WEB STRINGER 22 AREA. REMOVED DAMAGED AREA AND INSTALLED REPAIR, SRM 51-40-3 .050 7075-T6, REPAIR MATERILA AND .1875 FLUSH AND PAN 'D' RIVETS. (M)