What was found
TUL - FOUND CORROSION INSIDE STRINGER CHANNEL BETWEEN RIVITS. INSTALLED STRINGER SPLICE SAME AS ORIGINAL MATERIAL PRODUCTION SPLICE EXCEPT EXTENDED THE SAME NR FASTENERS PAST DAMAGE PER ESO 11697 DATED 10/15/98. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - FOUND CORROSION INSIDE STRINGER CHANNEL BETWEEN RIVITS. INSTALLED STRINGER SPLICE SAME AS ORIGINAL MATERIAL PRODUCTION SPLICE EXCEPT EXTENDED THE SAME NR FASTENERS PAST DAMAGE PER ESO 11697 DATED 10/15/98. (M)