What was found
TUL - FOUND CORROSION FLOORBEAM STATION 1050 LB 10 TO LB 55. REMOVED CORROSION, CUTOUT, BEYOND LIMITS, AREA AND INSTALLED REPAIR PER SRM 53-10-8 PAGE 9A AND 9B. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - FOUND CORROSION FLOORBEAM STATION 1050 LB 10 TO LB 55. REMOVED CORROSION, CUTOUT, BEYOND LIMITS, AREA AND INSTALLED REPAIR PER SRM 53-10-8 PAGE 9A AND 9B. (M)