What was found
TUL - STATION 720A FRAME UPPER FLANGE DENTED BETWEEN STRINGER 24L AND 25L. CUT OUT DAMAGE AND INSTALLED REPAIR DOUBLER PER SRM 51-40-3. INSTALLED DOUBLER OVER DAMAGED AREA, DENT .050 FRAME, DOUBLER MATERIAL .050. SAME TYPE MATERIAL FASTENERS BAC 830 FM6 BACB30 FM8 FIVE ROWS ON BOTH SIDE OF DAMAGE. (M)