What was found
TUL - BELL FRAME DENTED STATION 680 BETWEEN STRINGER 22L AND 24L. CUT OUT DAMAGED AREA 4.5 L BY .5 W INSTALLED .050 DOUBLER 7075-T6 13 INCHES LONG. INSTALLED 17 FASTENERS THROUGH BELL FRAME UPPER FLANGE ON .75 INCH SPACING, 20 FASTENERS THROUGH SIDE ON 1 INCH SPACING (2 ROWS OF 10 EACH) FASTENER USED HI-LOCKS BACB30FP6-2, ORIG MATERIAL THICKNESS .050, HI-LOCKS BACB30FP6-4, SRM 53-10-4. (M)