As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
TUL - STATION 520 BELL FRAME DENTED BETWEEN STRINGER 23L AND 25L. CUT OUT DAMAGE AT TWO LOCATIONS. 1 INCH BY 4 INCH AT STRINGER 23L, 1 INCH BY 3 INCH AT STRINGER 25L. EACH AREA HAD SEPARATE DOUBLERS INSTALLED PER SRM 51-40-3 USING 7075-T6 .050 THICK DOUBLER MATERIAL. (M)