What was found
TUL - FOUND CORROSION ON FLOORBEAM STATION 380 RBL 20 TO RBL 45. CUT OUT UPPER PORTION OF FLOORBEAM TO REMOVE CORROSION AND INSTALLED DOUBLER REPAIR PER SRM 53-10-8. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - FOUND CORROSION ON FLOORBEAM STATION 380 RBL 20 TO RBL 45. CUT OUT UPPER PORTION OF FLOORBEAM TO REMOVE CORROSION AND INSTALLED DOUBLER REPAIR PER SRM 53-10-8. (M)