As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFW - FLOORBEAM AT STATION 347 HAD AREAS OF CORROSION BLENDED BEYOND SRM LIMITS. FABRICATE REPAIR STRAP OUT OF 301.5 SS .050. ALODINE ALL BARE ALUM SURFACES FINISH BLENDS AND REPAIR PARTS WITH 2 COATS BMS 10-11 PRIMER. FILL BLENDS WITH BMS 5-92, INSTALL STRAP WET W/BMS 5-95 SEALANT, PROSEAL 870 REPAIR PER MRB 767-1980. (M)