SDR AALA990296

Service difficulty report · Valve · Boeing 727223

Difficulty date
March 1, 1999
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N713AA
Make and model
Boeing 727223
Aircraft serial
22469
Part
Valve
Part number
32146451
Condition
Defective
Location
Nr 1 Engine
Stage of operation
CL
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

MIA - FLT 2115 - DURING CLIMB-OUT, NR 1 BLEED OVER PRESSURE LIGHT ILLUMINATED. CREW RAN CHECKLIST AND AIR INTERRUPTED, RETURNED TO MIA AND LANDED WITHOUT FURTHER INCIDENT. MAINTENANCE FOUND NR 1 ENGINE BLEED VALVE DEFECTIVE. REPLACED NR 1 ENGINE BLEED VALVE AND ENGINE RUN INDICATED NO LEAKS WITH SYSTEM OPERATING NORMALLY. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)