As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT FLOOR PATH LIGHTS INOPERATIVE FROM AFT OF FIRST CLASS CABIN TO FORWARD OVERWING EXIT DOOR. REPLACED CONNECTOR TO EMERGENCY EXIT FLOOR PATH LIGHTING BETWEEN FIRST CLASS CABIN AND FORWARD OVERWING EXIT DOOR. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)