As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFW - FLOORBEAM AT STATION 347 HAD CORROSION ON TOP SURFACE BLENDED BEYOND SRM LIMITS. FABRICATE REPAIR STRAP OF 301..5H SS, .050 INCH THICK, ALODINE ALL BARE ALUM FINISH BLENDS AND REPAIR PARTS WITH 2 COATS BMS 10-11 PRIMER. FILL BLENDS W/BMS 5-92. INSTALL REPAIR STRAP WET W/BMS 5-95 SEALANT, PROSEAL 970 MRB REPAIR 767-1982. (M)