As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFW - FLOORBEAM AT STATION 1480 HAD CORROSION ON TOP SURFACE BLENDED BEYOND SRM LIMITS. FABRICATE REPAIR STRAP OF 301.5H SS .050 INCH CHICK. ALODINE ALL BARE ALUM SURFACES, FINISH BLENDS AND REPAIR PARTS W/2 COATS BMS 10-11 PRIMER FILL BLENDS WITH BMS 5-92. INSTALL STRAP WET W/BMS 5-95. PROSEAL 870 MRB767-1983. (M)