What was found
STATION 1562L FOUND CORROSION ABOVE OUTFLOW VLV ON STRINGER. R & R STRINGER 31 LT AT STATION 1540 IAW SRM 53-00-03. SDR INFO, PN 146T3008, PART NAME, STRINGER, SN, NSN, CORRODED: LEVEL 2, EXACT FS & BS LOCATION ON ACFT 1540.00 TO 1543.00. EXACT STRINGER & WS LOCATION ACFT, STRINGER 31L TO 31L. ACFT WAS GNDED.