What was found
RIGHT WING OTBD INTERNAL LE AIR LOAD STRUT HAS CORROSION, AT FWD END & ON WIRE CLAMP STANDOFF, AT APPROX LES 612, INBD OF NR 9 SLAT, OTBD AUXILIARY TRACK. R & R AIR LOAD STRUT IAW SRM 51-40-02. SDR CORRODED, LEVEL 2, PN 114T2210-16, PART NAME RIB, SN NSN, EXACT STRINGER & WS LOCATION, FROM RT WING STATION 612. ACFT WAS GNDED.