What was found
DURING HFEC SURFACE SCAN FOUND END OF CRACKS MENTIONED ON NON-ROUTINE 1369 & MARKED END OF CRACK LOCATIONS WITHIN TRIM OUT LIMITS. ACCOMPLISHED TRIM OUT OF FAIL-SAFE IAW EA 53500013-003 & DOCUMENT 47008ORD03. SDR INFO 1/4" CRACKED, PN 145T2524, PART NAME, LEFT FAIL-SAFE STRAP, SN NSN, FS & BS LOCATION STATION 955. ACFT WAS GNDED.